DHW station BM-WP 4

DHW STATION

BM-WP 4

  • for heat pumps and with step a valve technology

Specifications:

Heating primary
Buffer tank
Heating secondary
Heating

Drinking water
Pressure stage: PN 6 PN 6 PN 10
Max. temperature: 90 °C 90 °C 75 °C
Connection dimensions: DN 25 DN 20 DN 20
Threads: 1" female threads ¾" female threads ¾" female threads


Drinking water heating using the flow principle:

The DHW is heated up in the flow principle only during demand via a stainless steel plate heat exchanger. A temperature and flow sensor based on the vortex principle determines the flow rate and the hot water temperature. The controller regulates the necessary heating energy for the plate exchanger via a step a valve stepper motor valve. The plate exchanger is not kept warm. This avoids unnecessary circulation loss and effectively prevents increased legionella formation.

4-pipes system:
An extra heat meter fitting is integrated in the cabinet for recording the consumption of the floor heating / radiator heating.